Renesas Electronics /R7FA6M1AD /RTC /RCR2

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as RCR2

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)START 0 (0)RESET 0 (0)ADJ30 0 (0)RTCOE 0 (0)AADJE 0 (0)AADJP 0 (0)HR24 0 (0)CNTMD

AADJP=0, START=0, RESET=0, RTCOE=0, AADJE=0, CNTMD=0, HR24=0, ADJ30=0

Description

RTC Control Register 2

Fields

START

Start

0 (0): Prescaler and time counter are stopped.

1 (1): Prescaler and time counter operate normally.

RESET

RTC Software Reset

0 (0): Writing is invalid.(write) / In normal time operation, or an RTC software reset has completed.(read)

1 (1): The prescaler and the target registers for RTC software reset *1 are initialized.(write) / During an RTC software reset.(read)

ADJ30

30-Second Adjustment

0 (0): Writing is invalid.(write) / In normal time operation, or 30-second adjustment has completed.(read)

1 (1): 30-second adjustment is executed.(write) / During 30-second adjustment.(read)

RTCOE

RTCOUT Output Enable

0 (0): RTCOUT output disabled.

1 (1): RTCOUT output enabled.

AADJE

Automatic Adjustment Enable (When the LOCO clock is selected, the setting of this bit is disabled.)

0 (0): Automatic adjustment is disabled.

1 (1): Automatic adjustment is enabled.

AADJP

Automatic Adjustment Period Select (When the LOCO clock is selected, the setting of this bit is disabled.)

0 (0): The RADJ.ADJ[5:0] setting value is adjusted from the count value of the prescaler every minute.

1 (1): The RADJ.ADJ[5:0] setting value is adjusted from the count value of the prescaler every 10 seconds.

HR24

Hours Mode

0 (0): The RTC operates in 12-hour mode.

1 (1): The RTC operates in 24-hour mode.

CNTMD

Count Mode Select

0 (0): The calendar count mode.

1 (1): The binary count mode.

Links

()